Trusculpt ID Body Shape Sculpting RF Monopolar Machine

R180,000.00

Trusculpt Slimming Machine
Handle pieces
10 pcs
Technology
Mono-polar radio frequency
Frequency
1MHz/2MHz
Input voltage
AC110V/220V
Output power
10-800W
Fuse
5A
Treatment temperature
41℃-55℃

This device is a state-of-the-art, radiofrequency energy-based treatment with real-time temperature control. The ID Fat Dissolver is a non-invasive, comfortable monopolar radiofrequency (RF) device that offers unique handle placement versatility to treat the entire abdomen or multiple body areas simultaneously. Fast, reliable, comfortable, clinically proven to permanently remove stubborn fat cells from the belly, flanks, arms, bra straps, legs, double chin and knees, in addition to fat reduction, RF energy boosts collagen regeneration, improves skin sagging and wrinkles, improves the overall contours of the face & jaw line, making the face & body skin firm & smooth, reducing fat, shaping & firming the skin.
The device is equipped with 10 treatment handle pieces with unique radio frequency, and various pieces are used on different parts, with no consumables, pain, nor downtime & return to normal activity immediately.

10 handle pieces meeting various needs

Flat fixed 6 handles 40cm² handles are fixed placed on multiple local fat pockets of the body at the same time. 6 treatment areas covering the abdomen and flanks up to 300 cm². Apply to entire body area. 1 point (40cm²) treatment time: 30-40 minutes.

Flat fixed-point 2 handles, used for fixed-point treatment of fat deposits, smaller than the temple area.
The handle covers a small area of 16 cm2 and treats in 5 minutes. Is suitable for double chin, pouty corners of the mouth, front breasts & fat accumulation on the knees. 1 spot treatment time: 5 minutes.

Large area sliding, 1 handle for sliding treatment on medium target or larger target area. Larger area than the traditional mobile radio frequency, large-scale body carving, suitable for waist, abdomen, arms, back, inner/outer thigh, buttocks/bottom edge. Treatment time: 25-60 minutes.

1 small-area sliding handle is used for sliding treatment on the face, suitable for the face.
Treatment time: 15-30 minutes.

Unique handle design provides even heat to the area, eliminating potential hot spots & enhancing safety & comfort, monopolar radiofrequency therapy with a target temperature above 44°C.

Each flank treatment is 30 minutes long & the abdominal treatment is 30 minutes long. Photographic & ultrasound evaluations show positive improvement after one month of treatment. The treatment was well tolerated by the subject, with no recovery period or prolonged discomfort post treatment.

The heat is slowly transferred from the deep layer to the surface layer, so the heat rise felt by subjects will be slower. The thicker the fat, the hotter the subcutaneous fat. When the set temperature is reached, the heating will automatically stop & the surface layer will remain at a constant temperature (set temperature) of 45°C, warm without any burning sensation. When the temperature is lower than the set temperature, it will automatically start heating, clinical histology shows that it has been clinically proven that the ID fat dissolving instrument can cause inflammation & fat necrosis below the dermis to a depth of 1.5 cm. Histological findings are complemented by clinical studies showing an average 26% reduction in fat as measured by ultrasound.

Mode of operation
Uses 2MHZ monopolar radio frequency providing uniform energy to the fat layer, maintaining a comfortable skin temperature. Allows treatment of multiple areas of the body simultaneously for maximum results & satisfaction, with real-time temperature control continuously monitoring skin temperature & automatically adjusts energy delivery to comfortably heat the skin maintaining at 45°C with a lower surface temperature than the deep fat. Fat heating selectivity optimizes energy delivery & heating enhances selective apoptosis within the subcutaneous adipose tissue. On average, 24-27% of fat cells were irreversibly damaged, the damaged fat cells were slowly broken down & eliminated from the treated subcutaneous fat tissue over a 12-week period. 12 weeks after treatment, about 24 percent of fat cells were irreversibly damaged, causing them to be excreted by the body.